| The Starvox 2 X 670W MODEL NO. 703-12X2 (REDUNDANT) switch mode power supply is listed below. The parameters common to all the modules are listed in the specifications, mechanical drawing section. | |||
| Other Voltage/Current Ratings can be supplied within overall wattage ratings. Consult STARVOX with your requirements |
|
|||
Parameters |
Specifications |
||
| AC Input Range | 176VAC-264VAC single phase 50Hz | ||
| Input Frequency Variation | 47Hz to 63Hz | ||
| Output Power | 2X 670 Watts | ||
| Output Voltage/ Currents | 5V DC 100A --------] +12VDC 10A ----------] -12VDC 4A ------------] In each Module |
||
| Output Voltage Adjustment | All outputs are adjustable to +/- 10% of the nominal rating by multiturn potentiometer provided on the real panel. | ||
| Marginal setting for +5VDC (through a toggle switch) | + / - 5% : Nominal (Nominal means 5VDC). | ||
| Load regulation for all Outputs (for load variation From 10% to full load on the measured output. Other outputs are at 10 % of their rated full load). | 0.2% for 5V 2% for +/- 12V |
||
| Line Regulation for all outputs (for input variation from 176V AC to 246V AC all outputs are at a full load). |
|
||
| Ripple (PK-PK) all the outputs are to be load fully at 230V AC input. | + 1% of rated outputs | ||
| Noise (PK-PK) (10Hz to 30 mHz) all outputs are to be loaded fully at 230V ACI/P. | +/-2% of the rated O/Ps. | ||
| Turn-on Time | Less than 1 sec. between application of AC Power and rise of all outputs to nominal value. | ||
| Inrush Current |
|
||
| Over temperature protection | Automatic shut down when internal temperature exceed maximum safe ratings. Automatic reset when temperature returns to acceptable level. | ||
| Soft Start | This built-in to climinate over shoot at the O/P during turn on. | ||
| Over Current Protection Short Circuit Protection | Oscillatory type for 5V and Fold back type for +/- 12V with (110 to 120%) automatic recovery after removal of over load or short circuit. | ||
| Reverse Voltage Protection | All outputs is inherently protected against reverse output voltage. | ||
| Over Voltage Protection | The Inverter shuts down whenever an over voltage condition exists on any output. Trip point is set to 120-135% of nominal. OVP circuit is reset by recycling AC Power. | ||
| Hold-up Time | All outputs remain within specified regulation for a minimum of 30m sec. at nominal line and full load. | ||
| Dynamic response for 5V DC | A step load change of +/-25% of the rated max current will change max. change of +/-3%, in the O/P voltage and the O/P will recover to +/-1% of the nominal DC O/P voltage in 0.5msec. | ||
| Efficiency | Not less than 65% at full load and over the entire AC I/P range. | ||
| Break down test | 1500V DC for 1 min. a) Between I/P and O/P terminals. b) Between I/P and chassis. |
||
| Insulation test | 100 MG ohms, when applied between O/P terminals and chassis. | ||
| Cooling | Forced Air-cooling. | ||
| Output termination | Outputs with sense from each module to be terminated on TB at the Back of the unit separately. | ||
| Dimension | 300 mm(H) X 426mm (W) X 300mm (D). | ||